2.5 Causes and countermeasures for ELECYLINDER alarms
C2-35
ME0384-4A
M
ai
nt
ena
nc
e
Sec
tion
C
ha
pt
er
2
Tr
oubl
es
hoot
in
g
[Warning: Maintenance warning 1]
This is an alert that the target value of the "total travel count" set by the customer has been
reached.
No.
Cause
Countermeasure
1
For safe use and long service life of the
ELECYLINDER, periodic lubrication is
recommended.
* To disable this warning, change the target
value to 0.
[Countermeasure 1]
Perform maintenance and inspection such as
greasing.
→
For how to grease, refer to the instruction
manual for each ELECYLINDER.
[Countermeasure 2]
When updating this function, be sure to set the
target value to a value larger than the current
value.
* For details on the maintenance warning settings, see "1.4 Maintenance Information" in
"Maintenance Section".
[Warning: Maintenance warning 2]
This is an alert that the target value of the "total travel distance" set by the customer has been
reached.
No.
Cause
Countermeasure
1
For safe use and long service life of the
ELECYLINDER, periodic lubrication is
recommended.
* To disable this warning, change the target
value to 0.
[Countermeasure 1]
Perform maintenance and inspection such as
greasing.
→
For how to grease, refer to the instruction
manual for each ELECYLINDER.
[Countermeasure 2]
When updating this function, be sure to set the
target value to a value larger than the current
value.
* For details on the maintenance warning settings, see "1.4 Maintenance Information" in
"Maintenance Section".
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......