6.1 Parameter
B6-8
ME0384-4A
St
art
up
Se
ctio
n
[Soft Limit + Side, Soft Limit - Side (Parameter No. 3, No. 4)]
No.
Name
Unit
Input range
Default initial value setting
3
Soft limit + side
mm
(deg) -9,999.99 to 9,999.99
Actual stroke on + side
4
Soft limit - side
mm
(deg) -9,999.99 to 9,999.99
Actual stroke on - side
0.3 mm (deg) is added to the outside of the effective actuator stroke for the default setting.
Change as required to prevent collision when there are obstacles, or when used slightly above
effective stroke within the movable range.
The minimum setting unit is 0.01mm.
Caution
●
At this time, take extra care not to set incorrect values as this will lead to a collision with
the mechanical end.
●
If changing, set a value extended by 0.3 mm to the outside of the effective stroke.
Example) To set the effective stroke between 0.0 mm and 80.0 mm
Parameter No.3 (+ side) 80.3
Parameter No.4 (- side) -0.3
The movable range of jog or inching after home return will be 0.2 mm inside the set value.
Alarm code 0D9 "Software limit over error" occurs when the set value exceeds the value set in
parameter No. 88 "Soft limit margin" (default setting = 0). If parameter No. 88 is not set, the
value set for this parameter will become a detection value of the alarm code 09D "Software limit
over error."
Approx. 0.3mm
0.0
0.2 mm
Effective stroke
Software limit to set for the parameter
Approx. 0.3mm
0.2mm
80.0
Jog/inching movable range after home return
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......