3.7 Address Configuration
A3-67
ME0384-4A
Spec
ifi
cat
ion
s
Sec
tion
Chapt
er 3
G
at
eway
Uni
t
[I/O Signal List]
Direct numerical control mode
(ON = corresponding bit is "1", OFF = corresponding bit is "0")
Signal type
Bit
Signal
name
Content
Details
PLC
out
put
Pushing
current
limit
value
16-bit
data
-
Set the current limit value in push-motion
operation. (Unit %)
The setting range is 0 to 200%, where 255 =
100% and 510 = 200%.
Ex) To set to 50%, specify 255
×
50% = 127.
Page
A3-121
Control
signal
b15
BKRL
Forced brake release
3.8 [15]
b14
INC
Incremental
[OFF: absolute position command,
ON: relative position command]
3.8 [20]
b13
DIR
Specified push direction
[ON
: travel in home reverse direction,
OFF: travel in home direction]
(Note) This signal is enabled when CON
push-motion method is selected.
3.8 [17]
b12
PUSH
Push-motion specification
[ON: push-motion operation, OFF: positioning operation]
3.8 [16]
b11
-
Not available
-
b10
b9
b8
JOG+
+Jog [ON: travel in home reverse direction, OFF: Stop]
3.8 [10]
b7
JOG-
-Jog [ON: travel in home direction, OFF: Stop]
b6
JVEL
Jog velocity/inching distance switchover
[OFF: Uses RCON parameter No. 26 "Jog
velocity" and No. 48 "Inching setting value"
ON: Uses RCON parameter No. 47 "Jog velocity
2 setting value or command vel. setting
value"
(Note 1)
and No. 49 "Inching 2 setting
value"]
3.8 [11]
b5
JISL
Jog/Inching switching [ON: Inching, OFF: Jog]
3.8 [12]
b4
SON
Servo ON command [ON: Servo ON, OFF: Servo OFF]
3.8 [5]
b3
RES
Reset [ON to execute reset]
3.8 [4]
b2
STP
Pausing [ON: Pause, OFF: Pause cancel]
3.8 [8]
b1
HOME
Home return
[ON to execute home return command. Even
when turned OFF midway, it will run until
completion]
3.8 [6]
b0
CSTR
Positioning start
[ON to execute travel command. Even when
turned OFF midway, it will run until completion]
3.8 [7]
Note 1: When command speed setting = 0: operates at the value of RCON parameter No. 47
"PIO Jog
velocity 2". When command speed setting ≠ 0: operates at the command
speed set value.
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......