2.5 Causes and countermeasures for ELECYLINDER alarms
C2-32
ME0384-4A
C
ha
pt
er
2
Troubl
es
hoot
ing
M
ai
nt
ena
nc
e
Sec
tion
[Alarm group B: Motor abnormality alarm]
Motor abnormality occurred.
No.
Cause
Countermeasure
1
The internal temperature of the motor may be
too high.
Improve the surrounding environment of the
motor so that the ambient temperature is 40 °C or
less.
If the abnormality is resolved upon turning the
power back on after the ambient temperature is
lowered, the internal temperature may have been
excessive.
[Countermeasure examples]
Remove the heat source/turn OFF the heat
source/install a fan/install a temperature
shield/improve thermal conductivity of the
base/install a heat dissipation fin, etc.
2
The ELECYLINDER may be being used under
conditions exceeding the specifications
described in the catalog.
Check the specification values such as payload,
acceleration/deceleration and speed, and adjust
them appropriately.
3
If this alarm recurs after performing the
inspection above and improving the power
supply environment, it is highly likely that the
motor has failed.
Replacement of the motor is required. For some
models, the motor cannot be replaced by the
customer. In that case, please contact IAI.
[Alarm group C: ELECYLINDER control unit abnormality alarm]
ELECYLINDER control unit abnormality occurred.
No.
Cause
Countermeasure
1
The ELECYLINDER control unit is affected by
the noise of a peripheral device and cannot
operate normally.
Shut down the power supply of the peripheral
device and operate only with the ELECYLINDER,
then check to see whether this alarm persists.
If it does not, there is a possibility that the
ELECYLINDER is affected by the noise from the
peripheral device.
Reconsider the noise countermeasures
(grounding, power line wiring, electrostatic
shielding, etc.) for the peripheral device.
2
If this alarm recurs after performing the
inspection above and improving the power
supply environment, it is highly likely that the
ELECYLINDER control unit has failed.
Replace the controller cover assembly of the
ELECYLINDER.
→
For the replacement method, refer to the
instruction manual for each ELECYLINDER.
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......