6.1 Parameter
B6-27
ME0384-4A
St
ar
tu
p
Se
ct
io
n
[S-Motion Ratio Setting (Parameter No. 56)]
No.
Name
Unit
Input range
Default initial value setting
56 S-motion ratio setting
%
0 to 100
0
Used when the value of "Acc/Dec mode" field in the position table is set to 1 (S-motion ratio
setting).
This softens the shocks of acceleration/deceleration without extending the cycle time.
S-motion is the sinusoidal waveform of a single cycle of acceleration time.
This parameter specifies degree of amplitude.
Setting [%]
Degree of amplitude
0
No S-motion (dotted line in the image diagram)
10
Amplitude of sinusoidal wave x 0.1 (solid line in the
image diagram)
50
Amplitude of sinusoidal wave x 0.5 (single-dot chain
line in the image diagram)
100
Amplitude of sinusoidal wave x 1 (double-dot chain line
in the image diagram)
Speed
Time
Within 2 seconds
0
Time
Speed
Amplitude
Acceleration
time
0
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......