6.1 Parameter
B6-25
ME0384-4A
St
ar
tu
p
Se
ct
io
n
[Acc/Dec Mode Initial Value (Parameter No. 52)]
No.
Name
Unit
Input range
Default initial value setting
52 Acc/Dec mode initial value
-
0: Trapezoid pattern
1: S-motion
2: First-order delay filter
0 (Trapezoid)
This value will be set automatically as "Acc/Dec mode" of the applicable position No. when the
target position is written in an unregistered position table.
For the acceleration/deceleration mode, refer to "3.7 Address Configuration / Position table
(page A3-48)".
[Stop Mode Initial Value (Parameter No. 53)]
No.
Name
Unit
Input range
Default initial value setting
53 Stop mode initial value
-
0 to 3 (Except for stepper
motor specification)
0 to 7 (Stepper motor
specification)
0
(Not in use)
A parameter to set the power-saving function.
For details, refer to "6.2 Various Functions / Power-saving function (page B6-75)".
[Current Control Width Number (Parameter No. 54)]
No.
Name
Unit
Input range
Default initial value setting
54 Current control width
number
-
0 to 15
In accordance with actuator
This parameter is a manufacturer adjustment parameter that determines the responsiveness of
the current loop control. Therefore, it must not be changed. The stability of the control system
may be impaired, which is extremely dangerous.
AC Servo Motor Specification and DC
brush-less motor specification only
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......