3.7 Address Configuration
A3-89
ME0384-4A
Spec
ifi
cat
ion
s
Sec
tion
Chapt
er 3
G
at
eway
Uni
t
[I/O Signal List]
EC Connection Unit
(ON = corresponding bit is "1", OFF = corresponding bit is "0")
Signal type
Bit
Signal name
Content
Details
PL
C
input
Status signal
(4th Axis)
b15
E3RD
Operation Ready
[On: Operation ready (servo on)]
Page
A3-116
b14
*ALM
Alarm (break contact)
[ON
:
No alarm
、
OFF
:
Alarm generated]
Page
A3-116
b13
LS1/PE1
Driving Forward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the forward end. It turns
on when pressing operation completes.]
Page
A3-115
~
116
b12
LS0/PE0
Driving Backward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the backward end. It
turns on when pressing operation
completes.]
Page
A3-115
~
116
Status signal
(3th Axis)
b11
E2RD
Operation Ready
[On: Operation ready (servo on)]
Page
A3-116
b10
*ALM
Alarm (break contact)
[ON
:
No alarm
、
OFF
:
Alarm generated]
Page
A3-116
b9
LS1/PE1
Driving Forward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the forward end. It turns
on when pressing operation completes.]
Page
A3-115
~
116
b8
LS0/PE0
Driving Backward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the backward end. It
turns on when pressing operation
completes.]
Page
A3-115
~
116
Status signal
(2nd Axis)
b7
E1RD
Operation Ready
[On: Operation ready (servo on)]
Page
A3-116
b6
*ALM
Alarm (break contact)
[ON
:
No alarm
、
OFF
:
Alarm generated]
Page
A3-116
b5
LS1/PE1
Driving Forward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the forward end. It turns
on when pressing operation completes.]
Page
A3-115
~
116
b4
LS0/PE0
Driving Backward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the backward end. It
turns on when pressing operation
completes.]
Page
A3-115
~
116
Status signal
(1st Axis)
b3
E0RD
Operation Ready
[On: Operation ready (servo on)]
Page
A3-116
b2
*ALM
Alarm (break contact)
[ON
:
No alarm
、
OFF
:
Alarm generated]
Page
A3-116
b1
LS1/PE1
Driving Forward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the forward end. It turns
on when pressing operation completes.]
Page
A3-115
~
116
b0
LS0/PE0
Driving Backward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the backward end. It
turns on when pressing operation
completes.]
Page
A3-115
~
116
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......