3.8 I/O Signals
A3-92
ME0384-4A
Chapt
er 3 G
at
eway
Uni
t
Spec
ific
at
ion
s S
ec
tion
[4] Reset (RES) PLC output signal
Operation mode Direct numerical control Simple direct Positioner 1 Positioner 2 Positioner 3 Positioner 5
○
: Y
×
: N
○
○
○
○
○
○
The reset signal RES has two functions: it resets the alarm when an alarm is generated and
suspends operation when it is in pause.
(1) If this signal is turned ON while an alarm of operation cancel level is being generated, the
alarm will be canceled. (For a cold start level alarm, the power must be turned on again.)
Check the cause of the alarm and resolve the cause before resetting the alarm. Resetting
the alarm repeatedly without resolving the cause and repeating the activation may cause
serious malfunction such as motor burnout.
(2) If this signal is turned from OFF to ON while paused, it is possible to cancel the remaining
travel distance and interrupt the operation.
[5] Servo ON command (SON)
PLC output signal
Servo ON status (SV)
PLC input signal
Positioning complete (PEND) PLC input signal
Operation mode Direct numerical control Simple direct Positioner 1 Positioner 2 Positioner 3 Positioner 5
○
: Y
×
: N
○
○
○
○
○
○
(1) The servo ON command signal SON is a signal that puts the actuator into an operable
status.
(2) When servo is turned ON and operation is enabled, the servo ON signal SV turns ON. At the
same time, the positioning complete signal PEND turns ON.
Also, the SYS of the driver unit LED of the corresponding axis No. on the front panel lights
up in green.
(3) Even if power is supplied to the controller, it cannot be operated while the SV signal is OFF.
When the SON signal is turned OFF while the actuator is in operation, the actuator stops
and the servo turns OFF.
For actuator with brake, the brake will activate.
Note 1: PEND is not turned on while in pause.
Servo ON command signal
SON
(PLC → RCON)
Servo ON status signal
SV
(RCON → PLC)
Positioning complete signal
PEND
(Note 1)
(RCON → PLC)
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......