3.8 I/O Signals
A3-129
ME0384-4A
Spec
ifi
cat
ion
s
Sec
tion
Chapt
er 3 G
at
eway
Uni
t
(2) For push-motion contactless
Even if it travels the distance set for positioning width, positioning complete signal PEND will not
be output if it has not pushed the workpiece (the current of the motor has not reached the
current limit value at the time of pushing). However, completed position No. is output.
At this time, PSFL of status signal bit 5 becomes "1" (ON).
(3) If the workpiece moves after pushing
■ If the workpiece moves in the pushing direction
Once the workpiece moves in the pushing direction after pushing is completed, the actuator
tracks the workpiece within the range of the positioning width.
If the traveling current value becomes smaller than the pushing current limit value, the
positioning complete signal PEND will be "0" (OFF). When it reaches the current limit value
again, it becomes "1" (ON).
■ If the workpiece moves in the direction opposite to the push direction (when the reaction force
from the workpiece is too strong and it is pushed back)
If pushed back due to reaction force from the workpiece after pushing is completed, the
actuator is pushed back to the utmost until the pushing force and the reaction force from the
workpiece are balanced.
At this time, the positioning complete signal PEND remains "1" (ON). When pushed back to
the target position, an alarm is generated.
If it has not pushed the workpiece
Positioning complete signal will not
turn ON
Positioning width
Target position
Travel distance
Speed
If the workpiece shifts backwards,
it tracks within the positioning width
range
Positioning width
Target position
Travel distance
Speed
Position at which
pushing complete
was determined first
Positioning width
Target position
Travel distance
Speed
Position at which pushing complete
was determined first
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......