2.4 Driver Unit/Simple Absolute Unit Alarm Causes and Countermeasures
C2-13
ME0384-4A
M
ai
nt
ena
nc
e
Sec
tion
C
ha
pt
er
2
Tr
oubl
es
hoot
in
g
Alarm
code
Alarm name
Causes/countermeasures
068
S
Driver
limited
SRAM access error
Cause: Servo monitor is not operated in the normal condition because
of noise or malfunction of consisting parts.
Countermeasure: 1) Take proper measures against noise.
2) When the servo monitoring function is not used,
set parameter No.112
“
Monitoring mode
”
to
“
0
”
.
3) If the operation is not improved in use of the
servo monitoring function in spite of measures
against noise, Please contact IAI.
06B
Maintenance information
data error
Cause: Maintenance information (total travel count, total travel
distance) has been lost.
Countermeasure: Contact IAI.
100~
1FF
Teaching tool alarm
[Refer to teaching tool instruction manual]
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......