6.1 Parameter
B6-37
ME0384-4A
St
ar
tu
p
Se
ct
io
n
[Monitoring Mode Select (Parameter No. 112)]
No.
Name
Unit
Input range
Default initial value setting
112 Monitoring mode select
-
0: Not in use
1: Monitor function 1
2: Monitor function 2
3: Monitor function 3
1
Servo monitoring can be performed by connecting PC software.
Select monitoring mode function (number of channels for servo monitor) with this parameter.
Refer to the manual for PC software (ME0155).
Set value
Content
0
Not in use
1
Set in 4CH record mode
2
Set in 8CH record mode
3
Set in 2CH record mode
[Monitoring Cycle (Parameter No. 113)]
No.
Name
Unit
Input range
Specification
Default initial
value setting
113 Monitoring cycle
ms
1 to 60,000
Stepper motor specification
24V AC servo motor specification
DC brush-less motor specification
1
1 to 1,000
200V AC servo motor specification
Sets initial value
(Note 1)
of time cycle (sampling cycle) to obtain data when monitoring mode is
selected.
Data obtaining interval can be extended by increasing the value of this parameter.
The initial value is set at 1ms. Up to 60,000 ms (Up to 1,000m for 200V driver unit) can be set in
1ms increments.
For RCON-PC/PCF/AC
For RCON-DC
1ms cycle setting 60,000ms cycle setting 1ms cycle setting 60,000ms cycle setting
During 4CH record mode:
Maximum 3,584 seconds
During 4CH record mode:
Maximum 59 hours and 44 minutes
During 4CH record mode:
Maximum 4,096 seconds
During 4CH record mode:
Maximum 68 hours and 16 minutes
During 8CH record mode:
Maximum 1,792 seconds
During 8CH record mode:
Maximum 29 hours and 52 minutes
During 8CH record mode:
Maximum 2,048 seconds
During 8CH record mode:
Maximum 34 hours and 8 minutes
During 2CH record mode:
Maximum 7,168 seconds
During 2CH record mode:
Maximum 119 hours and 28 minutes
During 2CH record mode:
Maximum 8,192 seconds
During 2CH record mode:
Maximum 136 hours and 32 minutes
Note 1: Sampling cycle can be changed by using PC software.
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......