[I/O Signal List]
Positioner 1/2 mode
(ON = corresponding bit is "1", OFF = corresponding bit is "0")
Signal type
Bit
Signal name
Content
Details
PLC
input
Present
position
data
32-bit
data
-
32-bit signed integer (unit: 0.01 mm;
0.001° for DD motor).
Ex) For +25.40 mm, outputs as 2540.
●
The maximum output value is
+9,999.99 mm = 999999.
●
For negative numbers, 2
ʼ
s complement
will be displayed when reading is made
in a hexadecimal number.
Page
A3-123
Complete
position
No.
b6-b0
PM**
Reads the completed position No. in binary.
Outputs the simple alarm code while alarm
is generated. (Refer to P. C2-10)
Page
A3-123
Status
signal
b15
EMGS Emergency stop status
[ON: Emergency stop status]
3.8 [2]
b14
CRDY Controller ready
[ON: Ready]
3.8 [1]
b13
ZONE2
Zone output monitor 2
[ON : Present position is within the setting range of zone 2,
OFF: Limited position is not within the setting range]
3.8 [9]
b12
ZONE1
Zone output monitor 1
[ON : Present position is within the setting range of zone
1,
OFF: Limited position is not within the setting
range]
b11
PZONE
Position zone output monitor
[ON when the present position is within
the position zone setting]
b10
MODES Teaching mode status
[ON for teaching mode]
3.8 [13]
b9
WEND Position data import complete
[ON when position data import completes]
3.8 [14]
b8
MEND
Command complete
[ON : When in positioning complete, push-motion
complete or idling status after travel,
OFF: Travel start or servo OFF]
3.8 [19]
b7
ALML
Minor malfunction alarm output
[ON: When overload warning or message
level alarm occurs]
3.8 [21]
b6
LOAD
Load output judgment status
[ON: When collision is detected]
3.8 [22]
b5
PSFL
Push-motion operation contactless
[ON: push-motion operation completed contactless] 3.8 [18]
b4
SV
Operation ready
[ON: Operation ready (Servo ON)]
3.8 [5]
b3
ALM
Alarm
[ON: Alarm generated, OFF: No alarm]
3.8 [3]
b2
MOVE Traveling
[ON: Traveling, OFF: Stopped]
3.8
[6] [7]
b1
HEND Home return complete
[ON: Maintaining home after home return complete]
3.8 [6]
b0
PEND
Positioning complete
[ON : After completion, stopped at servo ON,
OFF: For contactless push-motion,
stopped at servo OFF]
3.8
[5] ~ [7]
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......