3.7 Address Configuration
A3-88
ME0384-4A
Chapt
er 3 G
at
eway
Uni
t
Spec
ific
at
ion
s S
ec
tion
[I/O Signal List]
EC Connection Unit
(ON = corresponding bit is "1", OFF = corresponding bit is "0")
Signal type
Bit
Signal name
Content
Details
PLC
out
put
Control signal
(4th Axis)
b15
-
Not available
-
b14
RES
Alarm Cancel
[Alarm cancelled with on]
Page
A3-114
b13
ST1
Drive Forward
[Drives forward with on (drives forward
after home-return operation when home
return not complete), decelerate and stop
on the way with off]
Page
A3-113
b12
ST0
Drive Backward
[Drives backward with on (drives
backward after home-return operation
when home return not complete),
decelerate and stop on the way with off]
Page
A3-113
Control signal
(3th Axis)
b11
-
Not available
-
b10
RES
Alarm Cancel
[Alarm cancelled with on]
Page
A3-114
b9
ST1
Drive Forward
[Drives forward with on (drives forward
after home-return operation when home
return not complete), decelerate and stop
on the way with off]
Page
A3-113
b8
ST0
Drive Backward
[Drives backward with on (drives
backward after home-return operation
when home return not complete),
decelerate and stop on the way with off]
Page
A3-113
Control signal
(2nd Axis)
b7
-
Not available
-
b6
RES
Alarm Cancel
[Alarm cancelled with on]
Page
A3-114
b5
ST1
Drive Forward
[Drives forward with on (drives forward
after home-return operation when home
return not complete), decelerate and stop
on the way with off]
Page
A3-113
b4
ST0
Drive Backward
[Drives backward with on (drives
backward after home-return operation
when home return not complete),
decelerate and stop on the way with off]
Page
A3-113
Control signal
(1st Axis)
b3
-
Not available
-
b2
RES
Alarm Cancel
[Alarm cancelled with on]
Page
A3-114
b1
ST1
Drive Forward
[Drives forward with on (drives forward
after home-return operation when home
return not complete), decelerate and stop
on the way with off]
Page
A3-113
b0
ST0
Drive Backward
[Drives backward with on (drives
backward after home-return operation
when home return not complete),
decelerate and stop on the way with off]
Page
A3-113
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......