6.2 Various Functions
B6-72
ME0384-4A
St
art
up
Se
ctio
n
Collision detection function
This function stops the operation immediately when the actuator comes into contact with an
object.
Fully understand the descriptions in this section and use without any safety or operational issues.
The collision detection function is a function to stop operation by generating an alarm and
turning the servo OFF when the command current value exceeds the set value. Detection range
can also be set.
Caution
●
This is an auxiliary function to reduce damage to workpieces, etc. in case of
unexpected events.
●
This feature is not used in the direct indication mode.
●
No compensation will be offered for unexpected damages.
●
This function must be set in accordance with expected collisions, therefore appropriate
values vary depending on the system. Check thoroughly before use.
[Collision Judgment]
When the present position is within the position zone range and the time set in parameter No.
50 "Load output judgment time" is exceeded and the command torque value set in the position
table "Threshold" is exceeded, a collision is judged to have happened.
After judgment, the load output judgment status (LOAD) turns ON, the collision detection alarm
is generated and the servo turns OFF.
◎
Example of Judgment (at judgment time of 255 ms)
75ms
Due to load fluctuation
current drops
Occurrence of
collision
Current
Due to outside range
not counted
Current
limit value
when
traveling
"Threshold"
Set current
value
Travel start
position
Position zone
Within range
(judgment start)
Start counting
Count up to 200
Count up to 255
Time
LOAD
Collision detection alarm (0DF)
Servo control
Blinking green
Controller status indicator LED
Servo
OFF
Stepper motor specification only
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......