Actuator Control Command
348
z
MOVP (Move PTP by specifying position data)
Command, declaration
Extension
condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
E
N, Cnd
Cmnd
Operand 1
Operand 2
Pst
Optional Optional
MOVP
Position
number
Prohibited PE
Applicable models
All models [Refer to Section 5.1 for details of models]
{
[Function]
Move the actuator to the position corresponding to the position number specified
in operand 1, without interpolation (PTP stands for “Point-to-Point”).
The output will turn OFF at the start of axis movement, and turn ON when the
movement is complete.
(Note)
In XSEL-PX/QX, a movement to a position that indicates the target for SCARA
axis and linear drive axis at the same time cannot be made. (421 “SCARA/Linear
Drive Axes Double Indication Error”)
Use GRP Command, or operate the position data of SCARA axis and linear drive
axis separately.
(Other than SCARA robots)
[Example 1]
VEL
100
Set the speed to 100mm/s.
MOVP 1
Move the axes to the position corresponding to
position No. 1 (200, 100).
[Example 2]
VEL
100
Set the speed to 100mm/s.
LET
1
2
Assign 2 to variable 1.
MOVP *1
Move the axes to the position corresponding to the
content of variable 1 (position No. 2, or (100,
100)).
Position Data Display in PC Software
No.
Axis 1
(X-axis)
Axis 2
(Y-axis)
Vel Acc Dcl
1 200.000
100.000
2 100.000
100.000
(Note) If acceleration and deceleration are not specified by position data or ACC (DCL) commands, the actuator
operates at the default values set in all-axis parameter No. 11, “Default acceleration” and all-axis parameter No.
12, “Default deceleration”.
Travel path from the home to the position corresponding to position No. 1 (200, 100)
X-axis
Y-axis
Only the Y-axis
completes movement.
Each axis moves at 100mm/s.
Home 0
100mm
100mm 200mm
Содержание PSEL
Страница 2: ......
Страница 10: ......
Страница 18: ...8 Part 1 Installation ...
Страница 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Страница 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Страница 476: ...466 Appendix ...
Страница 480: ...470 ...
Страница 485: ...475 ...
Страница 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Страница 488: ......
Страница 490: ......
Страница 494: ......
Страница 518: ...24 ...
Страница 526: ...32 ...
Страница 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Страница 1060: ......
Страница 1061: ......