3. Program
175
3.6.6 Handling of WAIT Timers
WAIT timers are provided to wait for certain events to occur.
Use a TIMW command to specify waiting.
WAIT timers can be actuated in each program.
3.6.7 Handling of Shot Pulse Timers
Shot pulse timers provide a function to turn ON/OFF an I/O flag for a specified time.
You can use a BTPN command to turn ON an I/O or flag for a specified time.
Similarly, you can use a BTPF command to turn OFF an I/O or flag for a specified time.
The maximum number of shot pulse timers that can be actuated simultaneously in one
program is 16 as a total of BTPN and BTPF commands.
Note, however, that there are no limitations to how many times these timers can be used in
one program.