Input function specification value 9: Start-program number specification bit 1 (least significant
bit)
This bit specifies the least significant bit of a program number.
Note: Start-program number specification bits x (input function
setting values 9 through 15) cannot be assigned discontinuously
from the least significant bit or in descending order from the least
significant bit.
Input function specification value 10: Start-program number specification bit 2
This bit specifies the second bit of a program number.
Input function specification value 11: Start-program number specification bit 3
This bit specifies the third bit of a program number.
Input function specification value 12: Start-program number specification bit 4
This bit specifies the forth bit of a program number.
Input function specification value 13: Start-program number specification bit 5
This bit specifies the fifth bit of a program number.
Input function specification value 14: Start-program number specification bit 6
This bit specifies the sixth bit of a program number.
Input function specification value 15: Start-program number specification bit 7
This bit specifies the seventh bit of a program number.
Input function specification value 16: Error reset (ON edge)
This signal is used to reset errors.
Note: Only errors of operation-cancellation level or lower can be
reset using this signal.
Input function specification value 17: Drive-source cutoff reset input (ON edge) (Effective when the
problem factor has been removed)
This signal is used as a drive-source cutoff reset input when the
emergency stop/enable switch recovery type is set to “Operation
continued.”
Input function specification value 18: Home-return command signal for all valid axes (ON edge)
This signal commands home return of all valid axes.
Note: The servo ON input signal (input function specification
value 4) must be turned ON first.
Input function specification value 19: Home-return command signal for all incremental axes (ON
edge)
This signal commands home return of all incremental axes.
Note: The servo ON input signal (input function specification
value 4) must be turned ON first.
Input function specification value 20: PC/TP-servo movement command acceptance permission
input
Movements can be permitted from the PC software or teaching
pendant.
Содержание PSEL
Страница 2: ......
Страница 10: ......
Страница 18: ...8 Part 1 Installation ...
Страница 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Страница 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Страница 476: ...466 Appendix ...
Страница 480: ...470 ...
Страница 485: ...475 ...
Страница 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Страница 488: ......
Страница 490: ......
Страница 494: ......
Страница 518: ...24 ...
Страница 526: ...32 ...
Страница 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Страница 1060: ......
Страница 1061: ......