94
Part 2 Programs
Operation type in the output field
CC: Command was executed successfully, ZR: Operation result is zero,
PE: Operation is complete, CP: Command part has passed, TU: Time up
EQ: Operand 1 = Operand 2, NE: Operand 1
z
Operand 2,
GT: Operand 1 > Operand 2, GE: Operand 1
t
Operand 2,
LT: Operand 1 < Operand 2, LE: Operand 1
d
Operand 2
Category
Condition Command
Operand 1
Operand 2
Output
Function
Page
Optional
AXST
Variable number
Axis number
CP
Get axis status
199
Optional PGST Variable number
Program number
CP
Get program status
200
System
information
acquisition
Optional
SYST
Variable number
Prohibited
CP
Get system status
201
Optional
WZNA
Zone number
Axis pattern
CP
Wait for zone ON, with AND
202
Optional
WZNO
Zone number
Axis pattern
CP
Wait for zone ON, with OR
203
Optional
WZFA
Zone number
Axis pattern
CP
Wait for zone OFF, with AND
204
Zone
Optional
WZFO
Zone number
Axis pattern
CP
Wait for zone OFF, with OR
205
Optional
OPEN
Channel number
Prohibited
CP
Open channel
206
Optional
CLOS
Channel number
Prohibited
CP
Close channel
206
Optional
READ
Channel number
Column number
CC
Read from channel
207
Optional
TMRW
Read timer setting
(Write timer setting)
CP
Set READ timeout value
209
Optional
WRIT
Channel number
Column number
CC
Output to channel
211
Communica
tion
Optional
SCHA
Character code
Prohibited
CP
Set end character
212
Optional SCPY Column
number
Column number,
character literal
CC
Copy character string
213
Optional SCMP Column
number
Column number,
character literal
EQ
Compare character strings
214
Optional SGET Variable
number
Column number,
character literal
CP Get
character
215
Optional
SPUT
Column number
Data
CP
Set character
216
Optional
STR
Column number
Data
CC
Convert character string; decimal
217
Optional STRH Column
number Data
CC
Convert character string;
hexadecimal
218
Optional VAL Variable
number
Column number,
character literal
CC
Convert character string data;
decimal
219
Optional VALH Variable
number
Column number,
character literal
CC
Convert character string data;
hexadecimal
220
String
operation
Optional
SLEN
Character string length
Prohibited
CP
Set length
221
Содержание PSEL
Страница 2: ......
Страница 10: ......
Страница 18: ...8 Part 1 Installation ...
Страница 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Страница 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Страница 476: ...466 Appendix ...
Страница 480: ...470 ...
Страница 485: ...475 ...
Страница 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Страница 488: ......
Страница 490: ......
Страница 494: ......
Страница 518: ...24 ...
Страница 526: ...32 ...
Страница 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Страница 1060: ......
Страница 1061: ......