3. Program
152
[2] Ladder Statement Field
1) Extension
conditions
LD ·······LOAD
A ·······AND
O ·······OR
AB ·······AND BLOCK
OB ·······OR BLOCK
All of the above extension conditions can be used in non-ladder tasks.
2) Ladder
commands
OUTR ·········· Ladder output relay (Operand 1 = Output, flag number)
TIMR ··········
Ladder
timer
relay
(Operand 1 = Local flag number, Operand 2 = Timer setting (sec))
[3] Points to Note
x
This system only processes software ladders using an interpreter. Therefore, the processing
time is much longer than that of a dedicated commercial sequencer.
(This system is not suitable for large-scale ladder processing.)
x
If an extension condition is not specified for steps in which an input condition is specified,
the steps will be treated as LD (LOAD).
x
Always specify a “normally ON” contact for those steps that must be processed without fail,
such as CHPR, TSLP and GOTO. (LD 7001)
Virtual input 7001: “Normally ON” contact
Содержание PSEL
Страница 2: ......
Страница 10: ......
Страница 18: ...8 Part 1 Installation ...
Страница 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Страница 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Страница 476: ...466 Appendix ...
Страница 480: ...470 ...
Страница 485: ...475 ...
Страница 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Страница 488: ......
Страница 490: ......
Страница 494: ......
Страница 518: ...24 ...
Страница 526: ...32 ...
Страница 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Страница 1060: ......
Страница 1061: ......