401
Appendix
1. I/O
Parameters
1.1 I/O
Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
1 I/O
port
assignment
type
1
0 ~ 20
0: Fixed assignment
1: Automatic assignment (Priority: Network I/F module
o
Standard
I/O; * Ports are assigned only for the installed adjoining slots,
starting from the standard I/O slot = For safety reasons)
2
Input port start number
with fixed standard I/O
assignments (I/O1)
000
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set)
3 Output
port
start
number with fixed
standard I/O
assignments (I/O1)
300
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
4 ~
9
For future expansion
-1
-1 ~ 599
10
Standard I/O error
monitor
1
0 ~ 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power source)
3: Monitor (Monitor only errors relating to 24-V I/O power source)
* Some
exceptions
apply.
* If this parameter is set to “0” (= Do not monitor) or “2” (= Do not
monitor errors relating to 24-V I/O power source), a system error will
not generate even when the 24-V I/O power source presents
abnormality. However, the actual outputs from digital I/Os will be cut
off by circuitry thereafter to protect the controller.
11 ~
13
For future expansion
1
0 ~ 5
14
Network I/F module –
Number of remote
input ports used
0
0 ~ 256
Multiple of 8
15
Network I/F module –
Number of remote
output ports used
0
0 ~ 256
Multiple of 8
16
Network I/F module –
Beginning input port
number based on fixed
assignment
-1
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set)
17
Network I/F module –
Beginning output port
number based on fixed
assignment
-1
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
18
Network I/F module
error monitor
1
0 ~ 5
0: Do not monitor, 1: Monitor
* A system error will occur if a network link error remains for the
duration of the network link error check timer value or longer (refer
to I/O Parameter No. 120).
* Some
exceptions
apply.
19 (For
expansion)
0
20
Input filtering periods
2
1 ~ 9
msec Input signal is recognized when the status is held for twice the period
set by this parameter.
21 For
future
expansion
(change prohibited)
0 1
~
9
22
For future expansion
0
0 ~ 99999
msec
23
For future expansion
0H
0H ~
FFFFFFFFH
Содержание PSEL
Страница 2: ......
Страница 10: ......
Страница 18: ...8 Part 1 Installation ...
Страница 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Страница 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Страница 476: ...466 Appendix ...
Страница 480: ...470 ...
Страница 485: ...475 ...
Страница 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Страница 488: ......
Страница 490: ......
Страница 494: ......
Страница 518: ...24 ...
Страница 526: ...32 ...
Страница 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Страница 1060: ......
Страница 1061: ......