Tecnical Data / Model code
HYDAC Filtersysteme GmbH
en
Page 92
BeWa CS1000 3247149l en.doc
2006-07-24
19 Technical Details
General data
CS 12xx
CS 13xx
Mounting position
Arbitrary (recommendation: vertical direction of flow)
Self-diagnosis
continuously with error indication via status LED and display
Display (only CS 1x2x)
LED, 6-digit, in 17-segment format
Measured variables
ISO (ISO 4406:1999)
SAE (SAE AS 4059 (D))
ISO (ISO 4406:1987
NAS (NAS 1638)
Service variables
Flow ml/min
Out mA or VDC (according to model)
Drive %
Temp °C and °F
Ambient temperature range
-30 - +80°C ( -22 - 176°F)
Storage temperature range
-40 - +80°C ( -40 - 176°F)
Relative humidity
max. 95%, non-condensing
Material of seals
FPM -> CS 1xx0
EPDM -> CS 1xx1
Electrical safety class
III (low-voltage protection)
IP class
IP 67
Weight
1.3 kg
Hydraulic data
Measurement range
Display shows class from: ISO 7/6/5 - ISO 28/27/26
Calibrated within range ISO 13/11/10 - 23/21/18
Accuracy
+/- 1/2 ISO class in the calibrated range
Operating pressure
For the maximum permissible operating pressure, see rating
plate of CS 1000 or rating stamped on the underside.
Connectors
INLET: Thread G 1/4, ISO 228
OUTLET: Thread G 1/4, ISO 228
Permissible measurement flow rate
30 - 300 ml/min
Permissible viscosity range
1 - 1000 mm²/s
Fluid temperature range
0 - +85°C (32 - 185°F)