Analog output
HYDAC Filtersysteme GmbH
en
Page 57
BeWa CS1000 3247149l en.doc
2006-07-24
11.2.3 ISO Code (ISO), 3-digit
The ISO code signal consists of 3 measured values (> 4 µm(c) / > 6 µm(c) /> 14 µm(c)) and is time-
coded with the following time slices.
11.2.3.1 Time-coded
Signal
4.0
4.1
I (mA)
1
3
2
4
6
2
5
1
U (V)
t (ms)
4.8
19.2
High
High
Low
Low
300
3000
3000
3000
9.75
19.5
2.15
2.05
2.0
9.85
19.7
0.0
19.8
9.9
Ti
me
Signal
Size
Signal duration
per pulse in ms
Current (I) / Voltage (U)
1
Identifier
> 4 µm
(c)
300
High / Low
2
Measured value
> 4 µm
(c)
3000
Current / voltage for measured value (see table 11.2.1)
3
Identifier
> 6 µm
(c)
300
High / Low / High / Low
4
Measured value
> 6 µm
(c)
3000
Current / voltage for measured value (see table 11.2.1)
5
Identifier
> 14 µm
(c)
300
High / Low / High / Low / High / Low
6
Measured value
> 14µm
(c)
3000
Current / voltage for measured value (see table 11.2.1)
Содержание CS1000 Series