Analog output
HYDAC Filtersysteme GmbH
en
Page 58
BeWa CS1000 3247149l en.doc
2006-07-24
11.2.4 ISO + T (ISO+T)
The ISO+T signal consists of 4 measured values which are transmitted time-coded with the following
time slices:
11.2.4.1 Time-coded
Signal
4.0
2.0
4.1
2.05
I (mA)
U (V)
time (ms)
4.8
2.4
19.2
High
High
Low
Low
9.6
300
3000
3000
3000
1
2
4
6
8
3
5
7
19.5
9.85
4.3
2.15
19.7
9.75
0.0
19.8
9.9
Ti
me
Signal
Size
Signal duration
per pulse in ms
Current (I) / Voltage (U)
1
Identifier
> 4 µm
(c)
300
High / Low
2 Measured
value
> 4 µm
(c)
3000
Current / voltage for measured value (see table 11.2.1)
3
Identifier
> 6 µm
(c)
300
High / Low / High / Low
4 Measured
value
> 6 µm
(c)
3000
Current / voltage for measured value (see table 11.2.1)
5
Identifier
> 14 µm
(c)
300
High / Low / High / Low / High / Low
6 Measured
value
> 14 µm
(c)
3000
Current / voltage for measured value (see table 11.2.1)
7
Identifier
Temperature
300
High / Low / High / Low / High / Low / High / Low / High / Low
8 Measured
value
Temperature 3000
Current / voltage for measured value (see table 11.5.1)