Error Messages
HYDAC Filtertechnik GmbH
en
Page 79
BeWa CS1000 3247149l en.doc
2006-10-13
LED Blink code /
Display /
Analog Output /
SwitchOut
CS 1000 Status
To do
Error
No.
Red
19.9 mA / 9.95 V*
open
Defining flow not possible
Check flow. Increase or
reduce inlet pressure.
4
12.2 Exceptions Errors
LED
Blink code /
Display
CS1000 Status
To do
Error
No.
Red
4.1 mA / 2.05 V*
open
Firmware error
Reset device (re-supply
voltage to sensor) or contact
HYDAC
-1...-19
Red
4.1 mA / 2.05 V*
open
Communication error
Check wiring
-20...-39
Red
4.1 mA / 2.05 V*
open
General system error
Reset device (re-supply
voltage to sensor) or contact
HYDAC
-40...-69
Red
4.1 mA / 2.05 V*
open
Error during automatic
adjustment
Reset device (re-supply
voltage to sensor) /
check flow or contact HYDAC
-70
Red
4.1 mA / 2.05 V*
open
Error measuring cell LED
Reset device (re-supply
voltage to sensor) /
check flow or contact HYDAC
-100