8 Description of the Measuring Modes
After powering up, the CS 1000 automatically runs in one of the following measuring modes (set in
Power Up Mode).
8.1 Mode M1: Measure continuously
Application: Application:
Stand-alone
sensor
Active data outputs: Display & RS485 & analog output
Purpose: Measurement
only
Function:
Continuous measurement of solid contamination, without any switching
functions
8.2 Mode M2: Measure continuously and switch
Application:
Stand-alone sensor with monitoring of alerts
Active data outputs: Display & RS485 & analog output & switching output
Purpose: Continuous
measurement
and
triggering of signal lamps etc.
Function:
Continuous measurement of solid contamination, continuous monitoring of
programmable threshold; if threshold is exceeded, the switching output is
activated to monitor an alert on site
8.3 Mode M3: Filter down to contamination level and stop
Application:
Control of Filter Cart
Active data outputs: Display & RS485 & analog output & switching output
Purpose:
For cleaning up a hydraulic reservoir
Function:
Control of a filter unit, continuous measurement of solid contamination; if pre-
programmed cleanliness level is reached 5 times in sequence, the pump is
stopped