Analog output
HYDAC Filtersysteme GmbH
en
Page 65
BeWa CS1000 3247149l en.doc
2006-07-24
11.3.4 ISO + T (ISO+T)
The ISO+T signal consists of 4 measured values which are transmitted time-coded with the following
time slices:
11.3.4.1 Time-coded
Signal
11.3.4.1.1
4 – 20 mA Signal
4,0
2,0
4,1
2,05
I (mA)
U (V)
time (ms)
4,8
2,4
19,2
High
High
Low
Low
9,6
300
3000
3000
3000
1
2
4
6
8
3
5
7
19,5
9,85
4,3
2,15
19,7
9,75
0,0
19,8
9,9
Ti
me
SIgnal
Size
Signal duration
per pulse in ms
Current (I) / Voltage (U)
1
Identifier
> 2 µm
300
High / Low
2
Measured value
> 2 µm
3000
Current / voltage for measured value (see table 11.2.1)
3
Identifier
5 µm
300
High / Low / High / Low
4
Measured value
> 5 µm
3000
Current / voltage for measured value (see table 11.2.1)
5
Identifier
> 15 µm
300
High / Low / High / Low / High / Low
6
Measured value
> 15 µm
3000
Current / voltage for measured value (see table 11.2.1)
7
Identifier
Temperature
300
High / Low / High / Low / High / Low / High / Low / High / Low
8
Measured value Temperature
3000
Current / voltage for measured value (see table 11.5.1)
Содержание CS1000 Series