Measuring Menu:
Designation
DSPLAY
Select displayed measured variable
SWtOUT
Configure switching output
ANaOUT
Select measured variable for analog
output
CANCEL
Discard changes and exit
SAVE
Save changes and exit
Display — Select displayed measured variable when switching on the sensor
DSPLAY
Select displayed
measured variable
+
Designation
ISO
3-digit ISO code
NAS 2
NAS class 2
NAS 5
NAS class 5
NAS 15
NAS class 15
NAS 25
NAS class 25
NASMAX
NAS maximum
FLOW
Flow rate [in ml/min]
ANaOUT
Analog output [in mA]
DRIVE
LED current [in %]
TEMP C
Fluid temperature in °C (Celsius)
TEMP F
Fluid temperature in °F (Fahrenheit)
MODE – Configure measuring mode
For setting the switching output selected in the Power Up menu.
(Only the mode selected in the Power Up menu can be set here.)
SWtOUT
Configure switching
output
o.k.
Designation
M1
Measure continuously
M2
Measure continuously and switch
M3
Filter down to contamination level and
stop
M4
Filter to establish contamination levels
continuously
SINGLE
Perform single measu stop
M1
Measure continuously
o.k.
NO SET
M2
Measure continuously
and switch
o.k.
+
RELAY1
Measuring channel
MEAsCH
NASMAX