Analog output
HYDAC Filtersysteme GmbH
en
Page 50
BeWa CS1000 3247149l en.doc
2006-07-24
11.1.3.1 Time-coded
Signal
4.0
I (mA)
U (V)
t (ms)
4.8
Low
20.0
19.2
High
High
Low
4.5
4.3
4.1
19.7
19.5
300
3000
1
3
5
7
1
2
4
6
8
2.0
2.05
2.25
2.4
9.85
9.75
2.15
9.6
0.0
19.8
10.0
9.9
Ti
me
Signal
Size
Signal duration
per pulse in ms
Current (I) / Voltage (U)
1
Identifier
SAE A
300
High / Low
2
Measured value
SAE A
3000
Current / voltage for measured value (see table 11.1.1)
3
Identifier
SAE B
300
High / Low / High / Low
4
Measured value
SAE B
3000
Current / voltage for measured value (see table 11.1.1)
5
Identifier
SAE C
300
High / Low / High / Low / High / Low
6
Measured value
SAE C
3000
Current / voltage for measured value (see table 11.1.1)
7
Identifier
SAE D
300
High / Low / High / Low / High / Low / High / Low
8
Measured value
SAE D
3000
Current / voltage for measured value (see table 11.1.1)