Analog output
HYDAC Filtersysteme GmbH
en
Page 48
BeWa CS1000 3247149l en.doc
2006-07-24
11.1.1 SAE Signal Table
The current I=4.8 - 19.2 mA or voltage U=2.4 - 9.6 V DC corresponds to an SAE class SAE=0.0 - 14.0
or an error (resolution: 0.1 classes).
Current I
SAE class / Error
Voltage U
I< 4.0 mA
Cable break
U< 2.00 V
4.0 mA < I < 4.1 mA
Device error. Device not ready
2.00 V < U < 2.05 V
4.1 mA < I < 4.3 mA
Not defined
2.05 V < U < 2.15 V
4.3 mA < I < 4.5 mA
Flow error (flow too low)
2.15 V < U < 2.25 V
4.5 mA < I < 4.8 mA
Not defined
2.25 V < U < 2.40 V
I = 4.80 mA
SAE 0
U = 2.4 V
I = 4.90 mA
SAE 0.1
U = 2.45 V
I = 5.01 mA
SAE 0.2
U = 2.51 V
...
...
...
I = 5.83 mA
SAE 1
U = 2.92 V
I = 6.86 mA
SAE 2
U = 3.43 V
I = 7.89 mA
SAE 3
U = 3.95 V
I = 8.91 mA
SAE 4
U = 4.46 V
I = 9.94 mA
SAE 5
U = 4.97 V
I = 10.97 mA
SAE 6
U = 5.49 V
I = 12.00 mA
SAE 7
U = 6.00 V
I = 13.03 mA
SAE 8
U = 6.52 V
I = 14.06 mA
SAE 9
U = 7.03 V
I = 15.09 mA
SAE 10
U = 7.55 V
I = 16.11 mA
SAE 11
U = 8.06 V
I = 17.14 mA
SAE 12
U = 8.57 V
I = 18.17 mA
SAE 13
U = 9.09 V
...
...
...
I = 18.99 mA
SAE 13.8
U = 9.50 V
I = 19.10 mA
SAE 13.9
U = 9.55 V
I = 19.20 mA
SAE 14.0
U = 9.60 V
19.2 mA < I < 19.5 mA
Not defined
9.60 V < U < 9.75 V
19.5 mA < I < 19.7 mA
Flow error (flow too high)
9.75 V < U < 9.85 V
19.7 mA < I < 19.8 mA
Not defined
9.85 V < U < 9.90 V
19.8 mA < I < 20 mA
No measured value
9.90 V < U < 10 V
The current I or voltage U can be calculated for a given SAE class as follows:
I = 4.8 mA + SAE class * (19.2 mA - 4.8 mA) / 14
U = 2.4 V + SAE class * (9.6 V - 2.4 V) / 14
Содержание CS1000 Series