Installation and Operation
HYDAC Filtersysteme GmbH
en
Page 42
BeWa CS1000 3247149l en.doc
2006-07-24
9.4 Switching Behavior of the Switching Output
Mode 1 (M1)
Switching output CLOSED
Switching output OPEN
-
Always open
Mode 2 (M2)
Switching output CLOSED
Switching output OPEN
BEYOND
Beyond limit
≥
upper limit
After switching the unit on or starting a
measurement
Opens again when
≤
lower limit
BELOW
Below limit
≤
lower limit
After switching the unit on or starting a
measurement
Opens again when
≥
upper limit
WITHIN
Within range
Lower limit
≤
measured value
≤
upper
limit
After switching the unit on or starting a
measurement
Opens again when < lower limit or >
upper limit
OUTSDE
Outside range
Measured value
≤
lower limit or
Measured value
≥
upper limit
After switching the unit on or starting a
measurement
Lower limit < measured value < upper
limit
OFF
No switching
-
Always open
Mode 2 (M2)
For 3-digit ISO Code
Switching output CLOSED
Switching output OPEN
BEYOND
Beyond limit
A value
≥
respective upper limit
After switching the unit on or starting a
measurement
Opens again when all values
≤
respective lower limit
BELOW
Below limit
All values
≤
respective lower limit
After switching the unit on or starting a
measurement
Opens again when a value
≥
respective
upper limit
WITHIN
Within range
Respective lower limit
≤
all values
≤
respective upper limit
After switching the unit on or starting a
measurement
Opens again when one value < lower
limit or one value > upper limit
OUTSDE
A value
≤
respective lower limit or a
value
≥
respective upper limit
After switching the unit on or starting a
measurement