Analog output
HYDAC Filtersysteme GmbH
en
Page 77
BeWa CS1000 3247149l en.doc
2006-07-24
19.5 mA < I < 19.7 mA
Flow error (flow too high)
9.75 V < U < 9.85 V
19.7 mA < I < 19.8 mA
Not defined
9.85 V < U < 9.90 V
19.8 mA < I < 20 mA
No measured value
9.90 V < U < 10 V
The current or voltage can be calculated for a given temperature in °C or °F as follows:
I = 4.8 mA + (temperature [°C] + 25) * (19.2 mA - 4.8 mA) / 125
I = 4.8 mA + (temperature [°F] +13) * (19.2 mA - 4.8 mA) / 225
U = 2.4 V + (temperature [°C] + 25) * (9.6 V - 2.4 V) / 125
U = 2.4 V + (temperature [°F] + 13) * (9.6 V-2.4 V) / 225
The temperature in °C or °F can be calculated for a given current I or voltage U as follows:
Temperature [°C]= ((I - 4.8 mA)*(125 / 14.4 mA)) - 25
Temperature [°F]= ((I - 4.8 mA)*(225 / 14.4 mA)) - 13
Temperature [°C]= ((U - 2.4 V)*(125 / 7.2 V)) - 25
Temperature [°F]= ((U - 2.4 V)*(225 / 7.2 V)) - 13