Installation and Operation
HYDAC Filtersysteme GmbH
en
Page 35
BeWa CS1000 3247149l en.doc
2006-07-24
9.2.2 Measuring Menu (CS12xx)
The Measuring Menu allows you to change settings during operation.
Selection
How
Enter Measuring menu
Press button
o.k.
.
Scroll to CANCEL and actuate it
Scroll to CANCEL and press
o.k.
automatically after 30 s
without any action
Exit menu and save changes
Scroll to SAVE and press
o.k.
Measuring Menu:
Designation
DSPLAY
Select displayed measured variable
SWtOUT
Configure switching output
ANaOUT
Select measured variable for analog
output
CANCEL
Discard changes and exit
SAVE
Save changes and exit
Display — Select displayed measured variable when switching on the sensor
DSPLAY
Select displayed
measured variable
+
Designation
ISO
3-digit ISO code
SAE A
SAE class A
SAE B
SAE class B
SAE C
SAE class C
SAE D
SAE class D
SAeMAX
SAE A-D
FLOW
Flow rate [in ml/min]
ANaOUT
Analog output [in mA]
DRIVE
LED current [in %]
TEMP C
Fluid temperature in °C (Celsius)
TEMP F
Fluid temperature °F (Fahrenheit)
MODE – Configure measuring mode
For setting the switching output selected in the Power Up menu.
(Only the mode selected in the Power Up menu can be set here.)
SWtOUT
Configure switching
output
o.k.
Designation
M1
Measure continuously
M2
Measure continuously and switch
M3
Filter down to contamination level and
stop
M4
Filter to establish contamination levels
continuously
SINGLE
Perform single measu stop
Содержание CS1000 Series
Страница 97: ...Notizen Note Note ...
Страница 98: ...Notizen Note Note ...
Страница 99: ...Notizen Note Note ...