4.
Install the software on the server blade. The Quick Restore DVD is used for this purpose. See
“Recovering the X9720 Network Storage System” (page 125)
for more information.
5.
Set up fail over. For more information, see the HP StorageWorks X9000 File Serving Software
User Guide.
6.
Enable high availability (automated failover) by running the following command on server 1:
# ibrix_server –m
7.
Discover storage on the server blade:
ibrix_pv -a
8.
To enable health monitoring on the server blade, first unregister the vendor storage:
ibrix_vs -d -n <vendor storage name>
Next, re-register the vendor storage. In the command,
<sysName>
is, for example, x710.
The
<hostlist>
is a range inside square brackets, such as
X710s[2–4]
. If the first server
(
x710s1
in this example) is hosting the dedicated Management Server, do not include it in
the
<hostlist>
.
ibrix_vs -r -n <sysName> -t exds 172.16.1.1 -U exds -P <password>
-h <hostlist>
9.
If you made any other customizations to other servers, you may need to apply them to the
newly installed server.
80
Upgrading the X9720 Network Storage System hardware
Содержание StorageWorks X9720
Страница 137: ...13 When the Configure Network dialog box reappears select bond0 Configuring a file serving node 137 ...
Страница 178: ...English notice Estonian notice Finnish notice French notice 178 Regulatory compliance and safety ...
Страница 179: ...German notice Greek notice Hungarian notice Italian notice Waste Electrical and Electronic Equipment directive 179 ...
Страница 180: ...Latvian notice Lithuanian notice Polish notice Portuguese notice 180 Regulatory compliance and safety ...
Страница 181: ...Slovakian notice Slovenian notice Spanish notice Swedish notice Waste Electrical and Electronic Equipment directive 181 ...