X9000 RPC call to host failed
In
/var/log/messages
on a file serving node (segment server), you may see messages such
as:
ibr_process_status(): Err: RPC call to host=wodao6 failed, error=-651,
func=IDE_FSYNC_prepacked
If you see these messages persistently, contact HP Services as soon as possible. The messages
could indicate possible data loss and can cause I/O errors for applications that access X9000
file systems.
Degrade server blade/Power PIC
After a server blade or motherboard replacement, Insight Manager display on the blade chassis
may show an error message indicating that the power PIC module has outdated or incompatible
firmware. If this occurs, you can update the PIC firmware as follows:
1.
Log on to the server.
2.
Start hp-ilo:
# service hp-ilo start
3.
Flash the power PIC:
# /opt/hp/mxso/firmware/power_pic_scexe
4.
Reboot the server.
ibrix_fs -c failed with "Bad magic number in super-block"
If a file system creation command fails with an error like the following, it could be because the
segment creation command failed to preformat the LUN.
[root@eirosone1 configd]# ibrix_fs -c -f fs1 -s seg1_4
Calculated owner for seg1_4 : glory22
failed command (/usr/local/ibrix/bin/tuneibfs -F
3e2a9657-fc8b-46b2-96b0-1dc27e8002f3 -H glory2 -G 1 -N 1 -S fs1 -R 1
/dev/vg1_4/seg1_4 2>&1) status (1) output: (/usr/local/ibrix/bin/tuneibfs: Bad
magic number in super-block while trying to open /dev/vg1_4/seg1_4 Couldn't
find valid filesystem superblock. /usr/local/ibrix/bin/tuneibfs 5.3.461 Rpc
Version:5 Rpc Ports base=IBRIX_PORTS_BASE (Using EXT2FS Library version 1.32.1)
[ipfs1_open] reading superblock from blk 1 )
Iad error on host glory2
To workaround the problem re-create the segment on the failing LUN. For example to identify the
correct LUN associated with the failure above, run a command similar to the following on the first
server in the system. In the following example, server
glory2
is the name of a file serving node:
# ibrix_pv -l -h glory2
PV_NAME SIZE(MB) VG_NAME DEVICE RAIDTYPE RAIDHOST RAIDDEVICE
------- -------- ------- --------------- -------- -------- ----------
d1 131070 vg1_1 /dev/mxso/dev4a
d2 131070 vg1_2 /dev/mxso/dev5a
d3 131070 vg1_3 /dev/mxso/dev6a
d5 23551 vg1_5 /dev/mxso/dev8a
d6 131070 vg1_4 /dev/mxso/dev7a
The Device column identifies the LUN number. The volume group vg1_4 is created from LUN 7.
Re-create the segment according to the instructions in the HP StorageWorks X9000 File Serving
Software User Guide.
After this command completes, rerun the file system creation command.
108 Troubleshooting
Содержание StorageWorks X9720
Страница 137: ...13 When the Configure Network dialog box reappears select bond0 Configuring a file serving node 137 ...
Страница 178: ...English notice Estonian notice Finnish notice French notice 178 Regulatory compliance and safety ...
Страница 179: ...German notice Greek notice Hungarian notice Italian notice Waste Electrical and Electronic Equipment directive 179 ...
Страница 180: ...Latvian notice Lithuanian notice Polish notice Portuguese notice 180 Regulatory compliance and safety ...
Страница 181: ...Slovakian notice Slovenian notice Spanish notice Swedish notice Waste Electrical and Electronic Equipment directive 181 ...