4.
Confirm that automated failover is enabled:
<ibrixhome>/bin/ibrix_server -l
In the output,
HA
should display
on
.
5.
From the node hosting the active management console, perform a manual backup of the
upgraded configuration:
<ibrixhome>/bin/ibrix_fm -B
6.
Upgrade X9000 clients:
•
For Linux clients, see
“Upgrading Linux X9000 clients” (page 75)
.
•
For Windows clients, see
“Upgrading Windows X9000 clients” (page 75)
.
7.
Verify that all version indicators match for file serving nodes and X9000 clients. Run the
following command from the active management console:
<ibrixhome>/bin/ibrix_version –l
If there is a version mismatch, run the
/ibrix/ibrixupgrade -f
script again on the
affected node, and then recheck the versions. The installation is successful when all version
indicators match. If you followed all instructions and the version indicators do not match,
contact HP Support.
8.
Verify the health of the cluster:
<ibrixhome>/bin/ibrix_health -l
The output should show
Passed / on
.
9.
For an agile configuration, on all nodes hosting the passive management console, return the
management console to passive mode:
<ibrixhome>/bin/ibrix_fm -m passive
10.
If you received a new license from HP, install it as described in the “Licensing” chapter in this
document.
11.
Upgrade firmware on X9720 systems. See
“Upgrading firmware on X9720 systems” (page 76)
.
Upgrading Linux X9000 clients
Be sure to upgrade the management console and file serving nodes before upgrading Linux X9000
clients. Complete the following steps on each client:
1.
Expand the upgrade tarball or mount the upgrade DVD.
2.
Run the upgrade script:
./ibrixupgrade -f
The upgrade software automatically stops the necessary services and restarts them when the
upgrade is complete.
3.
Execute the following command to verify the client is running X9000 Software:
/etc/init.d/ibrix_client status
IBRIX Filesystem Drivers loaded
IBRIX IAD Server (pid 3208) running...
The
IAD
service should be running, as shown in the previous sample output. If it is not, contact HP
Support.
Upgrading Windows X9000 clients
Complete the following steps on each client:
Upgrading Linux X9000 clients
75
Содержание StorageWorks X9720
Страница 137: ...13 When the Configure Network dialog box reappears select bond0 Configuring a file serving node 137 ...
Страница 178: ...English notice Estonian notice Finnish notice French notice 178 Regulatory compliance and safety ...
Страница 179: ...German notice Greek notice Hungarian notice Italian notice Waste Electrical and Electronic Equipment directive 179 ...
Страница 180: ...Latvian notice Lithuanian notice Polish notice Portuguese notice 180 Regulatory compliance and safety ...
Страница 181: ...Slovakian notice Slovenian notice Spanish notice Swedish notice Waste Electrical and Electronic Equipment directive 181 ...