bladebay 2 add zonegroup=exds_zonegroup
bladebay 3 add zonegroup=exds_zonegroup
bladebay 4 add zonegroup=exds_zonegroup
bladebay 5 add zonegroup=exds_zonegroup
bladebay 6 add zonegroup=exds_zonegroup
bladebay 7 add zonegroup=exds_zonegroup
bladebay 8 add zonegroup=exds_zonegroup
bladebay 9 add zonegroup=exds_zonegroup
bladebay 10 add zonegroup=exds_zonegroup
bladebay 11 add zonegroup=exds_zonegroup
bladebay 12 add zonegroup=exds_zonegroup
bladebay 13 add zonegroup=exds_zonegroup
bladebay 14 add zonegroup=exds_zonegroup
bladebay 15 add zonegroup=exds_zonegroup
bladebay 16 add zonegroup=exds_zonegroup
switch local saveupdate
10. Verify that the zonegroups have been updated:
=> sw local zg exds_zonegroup show
Blade Enclosure at x123s-ExDS-ENC
Switch: Local
Zone Group: exds_zonegroup
Zoned Blade Switch Port: 41
Zoned Blade Switch Port: 42
Zoned Blade Switch Port: 43
Zoned Blade Switch Port: 44
Zoned Blade Switch Port: 45
Zoned Blade Switch Port: 46
Zoned Blade Switch Port: 47
Zoned Blade Switch Port: 48
Zoned Blade Switch Port: 31
Zoned Blade Switch Port: 32
Zoned Blade Switch Port: 33
Zoned Blade Switch Port: 34
Zoned Blade Switch Port: 35
Zoned Blade Switch Port: 36
Zoned Blade Switch Port: 37
Zoned Blade Switch Port: 38
Assigned Blade Bay: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
11. Reconnect the SAS cables.
12. Disconnect from the interconnect by pressing
Ctrl-Shift-_
(the Control, Shift, and underscore
keys) and then press the
D
key for "D)isconnect".
13. Exit from the OA using "exit".
NOTE:
Wait at least 60 seconds after seating the SAS switch before removing another SAS
switch.
The SAS switch now provides a redundant access path to storage. Storage units will balance I/O
between both switches on their subsequent restarts.
Replacing the P700m mezzanine card
1.
Shut down the server blade.
2.
Remove the server blade.
3.
Replace the P700m.
4.
Replace the blade in the original blade bay. The server automatically boots.
5.
Run the
exds_stdiag
command to validate the firmware version and that all capacity blocks
are seen by the server.
118
Replacing components in the X9720 Network Storage System
Содержание StorageWorks X9720
Страница 137: ...13 When the Configure Network dialog box reappears select bond0 Configuring a file serving node 137 ...
Страница 178: ...English notice Estonian notice Finnish notice French notice 178 Regulatory compliance and safety ...
Страница 179: ...German notice Greek notice Hungarian notice Italian notice Waste Electrical and Electronic Equipment directive 179 ...
Страница 180: ...Latvian notice Lithuanian notice Polish notice Portuguese notice 180 Regulatory compliance and safety ...
Страница 181: ...Slovakian notice Slovenian notice Spanish notice Swedish notice Waste Electrical and Electronic Equipment directive 181 ...