EMS Messages
Spooler FASTP Network Print Processes Manual — 427528-006
B - 131
FASTP EMS 512 Text Messages
Recovery.
Under normal circumstances, no operator intervention is required.
However, you can modify the supervisor’s response to this error by means of the
RECOVERY attribute in the FASTCNFG file. The default value is NORMAL, which
results in the behavior described above. If you set this attribute to REPRINT,
FASTPX25 returns to the first page of the job when printing is resumed.
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
x25su
is the X25AM subdevice.
fastcnfg
is the FASTCNFG file name.
Cause.
The X25AM SU value that corresponds to the X25NUA attribute in the
FASTCNFG file is configured to use a Permanent Virtual Circuit. The SU value
specified for X25NUA must be configured to use an SVC.
Effect.
The device is placed offline.
Recovery.
Specify an X25NUA attribute that corresponds to an SVC and restart the
device. (Depending on the device configuration, the device might restart automatically.)
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
proc-num
DEV:
device-name
X25NUA not permitted with PVC
SU
x25su
in
fastcnfg
proc-num
DEV:
device-name
XNS Close Connection Error
n