Spooler FASTP Network Print Processes Manual — 427528-006
B - 88
FASTP EMS 512 Text Messages
Cause.
This message applies to FASTPTCP only. FASTPTCP with
PROTOCOL=TCP/IP-TELNET and NOTIMINGMARK=NO expects a certain response
from the remote TELNET server (AWAN, terminal server, or other device) at the end of
the print job. Data was received other than a normal Do Timing Mark response. One
common cause is a printer that is sending XON or XOFF characters when the AWAN
or terminal server port is not configured for XON-XOFF. (Some printers send these
characters regardless of the setting of flow control as XON-XOFF, CTS, or disabled.)
XON and XOFF characters are displayed as hex 11 and 13.
Effect.
The print job is not closed in the Spooler, even though the job usually has been
completely printed. The device will be stuck on this print job, preventing other jobs from
printing.
Recovery.
If the job has completely printed, delete the job from the Spooler. If only
XON-XOFF characters are displayed in hex-data, reconfigure the AWAN or terminal
server port to use XON-XOFF, reconfigure the printer to suppress the XON-XOFF (if
possible), or disconnect the AWAN or terminal server RECEIVE DATA wire to disable
input from the printer. As a last resort, use NOTIMINGMARK=YES, but verify that no
data is lost, especially at the end of print jobs.
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
param-name
is the name of the parameter. The value is one of:
PRINTERADDRESS
ROUTER Address
SNETWORK
DNETWORK
DEPTH
TIMEOUT
HOLDOFF
CONTIMEOUT
CONRETRIES
proc-num
DEV:
device-name
Invalid
param-name
in
cnfg-file