EMS Messages
Spooler FASTP Network Print Processes Manual — 427528-006
B - 44
FASTPTCP Event Messages
73
proc-name
is the process name of the FASTPTCP process.
device-name
is the Spooler device name.
temp-name
is the name of the temporary disk file, either from the FASTCNFG parameter
TEMPFILE or a default name.
file-err
is a file-system error code. See the
Guardian Procedure Errors and Messages
Manual
for explanations of file-system errors.
Cause.
The FASTPTCP process uses a temporary file to stage print job data with
PROTOCOL=LPD. A file-system error was detected when using this file during a
PURGE operation.
Effect.
The Spooler job is terminated and requeued, and the Spooler device is placed
offline.
Recovery.
Purge the file specified for the TEMPFILE parameter for the device. If
TEMPFILE specifies a complete file name, either use a unique file name for each
device, change TEMPFILE to specify only a disk volume name, or completely omit the
TEMPFILE parameter. Verify that Safeguard permits access to the specified
TEMPFILE.
proc-name
DEV:
device-name
Tempfile
temp-name
PURGE
Err:
file-err