2-55
(4) Circulation system control data (SEQUENCE.TXT)
[Example]
- Code
Refer to the code of above example.
- Sequence name
Refer to the sequence name of above example.
- Result
0: Normal end, 1: Aborted, 2: Abnormal end
- Aborted step No.
Internal management code
- Info1-Info4
Internal management code
*) In case of change the ambient temperature upper limit on the system environment
screen, the before / after temperature value are indicated as below.
Before change: Info1
After change: Info2
(5) Trace data(TRACE.TXT
)
[Example]
№ Cod
e
Sequence name
Date
Time
Information
1 001
Power turned on
time
2014/01/22 9:20:00
2 009
CM clock
2014/01/22 9:20:00
[CCPU], 2014/01/22, 9:20:10,
[MCPU], 2014/01/22, 9:20:10
3 003
Select message
2014/01/22 9:25:35
0001, normal
- Code : refer to the next page.
- Sequence name: refer to the next page
- Info1-Info4 : refer to the each Logging contents
№
Date
Start time Finish timeCode
Sequence name
Result
Aborted
step №
info1
info2
info3
info4
1 2011/7/7
7:05:29
0:02:09
160 Eject ink B
3
0
0
0
0
0
2 2011/7/7
7:06:56
1:53:16
208 Noclean-stop
0
0
0
0
0
0
3 2011/7/7
8:06:56
0:05:35
80 Nozzle backwash
3
0
0
0
0
0
4 2011/7/7
9:07:45
0:22:42
32 Ink drainage
3
0
0
0
0
0
5 2011/7/7
10:12:04
0:08:47
176 Eject ink A
0
0
0
0
0
0
6 2011/7/7
11:37:20
0:16:57
192 Clean-stop
0
0
0
0
0
0
7 2011/7/7
12:07:22
0:03:51
96 Gutter cleaning
1
2
0
0
0
0
8 2011/7/7
12:14:45
1:00:00
246 Ambient temp. upper lim.
0
0
40
30
0
0
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...