6-20
6.2.18 Ink Heating Unit Over Current
- On detecting this fault, the IJ printer automatically sets the “Ink temperature
correction” to (disable).
“System environment setup: Ink temperature correction (enable)
(disable)”
After getting rid of the fault, reset the Ink temperature correction to (enable).
“System environment setup: Ink temperature correction (disable)
(enable)”
- In the condition of the “Ink temperature correction (disable), ” the “Ink Temperature
Correction Notice” message appears each time the power is turned on.
(See “1.6 Heating of Ink” in the Instruction manual”.)
Caution
!
Ink Heating Unit
Over Current
Is the PTC resistance
measured (between the
EZJ125 board TP3 and TP15)
lower than 23
Ω
?
No
Yes
Replace the heating unit.
Replace the EZJ125 board.
Does the fault recur?
Yes
No
▪
Clear the fault.
▪
From the maintenance screen, place
the heating unit in the operating mode. *)
▪
Restart the IJ printer.
Replace the print head.
Does the fault recur?
Yes
No
Resume the
operation.
Replace the EZJ126 board.
Does the fault recur?
No
Yes
▪
Clear the fault.
▪
From the maintenance screen, place
the heating unit in the operating mode. *)
▪
Restart the IJ printer.
▪
Clear the fault.
▪
From the maintenance screen, place
the heating unit in the operating mode. *)
▪
Restart the IJ printer.
*) Refer to the
following caution.
*) Refer to the
following caution.
*) Refer to the
following caution.
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...