4-12
4.5 Solenoid Valve Replacement Procedure
[Caution]
・
Work contents differ according to the solenoid valve No. to be replaced.
・
If the solenoid valve does not operate, conduct the replacement work with particular attention to
dripping.
1 Perform the following preparation for each solenoid valve that you are to replace.
Solenoid
valve No.
When the solenoid valve is working
When the solenoid valve is not working
MV1
Execute “Ink drainage”.
Drain the ink of the main ink tank from
the drain tube.
MV2
(1) Remove the tube connection
block of the ink reservoir.
(2)Turn on the pump, MV2, and
MV6 in this order for about one
minute, and then turn them off.
(Solenoid/Pump Test screen)
No operation is required.
(Pay attention to ink dripping.)
MV3
Execute “Gutter Cleaning”.
No operation is required.
(Pay attention to ink dripping.)
MV4
Execute “Ink drainage”.
No operation is required.
(Pay attention to ink dripping.)
MV5
Execute “Nozzle backwash”.
No operation is required.
(Pay attention to ink dripping.)
MV6
Execute “Ink drainage”.
No operation is required.
(Pay attention to ink dripping.)
MV7
Execute “Ink drainage”.
Drain the ink of the main ink tank from
the drain tube.
MV8
Execute “Pressure relief”.
No operation is required.
(Pay attention to makeup dripping.)
MV11(*1)
No operation is required.
(Pay attention to makeup dripping.)
No operation is required.
(Pay attention to ink dripping.)
MV12(*1)
Execute “Pressure relief”.
No operation is required.
(Pay attention to ink dripping.)
2 Turn off the power supply.
【
Work from the front
】
3 Perform “4.1.2 Access to the parts on the front side of the equipment”.
【
Work from the rear
】
3 Perform “4.1.3 Access to the parts on the rear side of the equipment”.
4 Remove the connector of the solenoid valve to be replaced.
*1 MV11 and MV12 are mounted on UX-E only.
Solenoid valve No.
Wire color
Solenoid valve No.
Wire color
Solenoid valve No.
Wire color
MV1
Brown
MV5
Green
MV11(*1)
Brown
MV2
Red
MV6
Blue
MV12(*1)
Red
MV3
Orange
MV7
Purple
-
-
MV4
Yellow
MV8
Gray
-
-
・
Parts inside the solenoid valve (diaphragm, etc.) cannot be replaced separately. In the case of
part failure, replace the entire solenoid valve.
・
The coil mold of the solenoid valve (black resin portion) is not resistant to solvents. Do not
immerse the coil mold in solvent. The coil mold however can be wiped gently with solvent.
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...