6-26
6.2.27 Circulation Route Pressure Is High
Circulation Route
Pressure Is High
Replace MV5 or clean any ink buildup or
other foreign matters.
Replace the circulation pump.
Press “Nozzle backwash” button and then
“Start/Continue” button on Circulation Control
screen and sprinkle makeup over the tip of the
nozzle.
Does the MV5 operate?
Yes
No
Does the fault recur?
Yes
No
Is makeup suctioned?
Yes
No
Resume the
operation.
<Conditions an alarm is issued>
An alarm “Circulation Route Pressure Is High” is displayed on the screen when the
ink is being ejected and the ink pressure is not lowered at MV5 “ON/Open” step in the
following sequences 1), 2) and 3).
(When Ink pressure is still kept at 0.05Mpa or higher.)
1) Eject Ink
(
Goes to Ready
)
2) Eject Ink
(
Goes to Standby
)
3)
Ink circulation
Refer to “7.3 Circulation sequence” for sequences.
Press “Operation test” button of “Viscometer calibration”
screen and confirm by the naked eye that ink flows to
the viscometer from the Main ink tank.
Does ink flow to the
viscometer from the Main
ink tank?
Yes
No
Does the fault recur?
Yes
No
Replace the print head.
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...