6-8
6.2.5 Ink Drop Charge Too Low
Pour a cleaning solution over
the orifice plate surface to
clean it, then allow it to
thoroughly dry.
If the problem is
not fixed:
If the problem is
not fixed:
Ink Drop Charge
Too Low
▪
Press the Reset key to
clear the fault.
▪
Eject the ink to restart the
IJ printer.
1
Are the charge electrode
and nozzle end connected
via ink?
Pour the makeup over the
charge electrode and nozzle
area to clean them and allow
them to thoroughly dry.
Is the cumulative ink
use time longer than
the useful ink life?
Replace the ink.
Yes
Yes
Yes
No
No
Is the ink drop shape good?
Change the excitation
voltage setting to assure
proper ink drop shape.
No
Yes
Is the nozzle clogged
or the ink stream bent?
1
No
Replace the EZJ126 board.
Remove the orifice plate from
the nozzle, subject it to
ultrasonic cleaning, reinstall
it, and adjust the stream.
Execute the “Nozzle
Backwash” function from the
circulation control screen.
If the problem is
not fixed:
Replace the print head.
Is the gutter section
soiled ?
Clean the gutter and its
surrounding area with a
cleaning solution. *1
Yes
No
If the problem is
not fixed:
Replace the EZJ125 board.
APH Shield
Gutter
Remove any dirt on this surface: If this surface is dirty, and the gutter
hole and APH shield are connected via ink, the APH signal output may
be unstable. Take special care when using carbon ink.
* 1
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...