4-3
<Cautions when Recovery filter base is removed>
When the Recovery filter base is removed, please confirm the following points as described in the figure
below.
・
Please confirm the Twist-Locks (Cable Fastener) are securely fastened to the Recovery filter
connecting tubes.
・
Please refer to the figure below and check the positions where the banding bands are placed.
Confirm the four pieces of banding bands are positioned as shown in the figure below. It shows the
locations of Banding bands and Twist-Locks.
<Cautions when Reservoir unit is pulled outside>
Please confirm following 2 points when the Reservoir unit is pulled outside as indicated in the figure in step
4 of “4.1.2 Access to the parts on the front side of the equipment”.
(a). The length of the recovery filter tubes is limited, only approximately 330mm. When the Reservoir unit is
pulled outside, remove the fixing screw (1 position) first, then hold the Recovery filter base with your hand
to remove the Reservoir unit from its original position. Carefully pull out the Reservoir unit, paying
attention so that the tubes cannot be caught.
(b). When the parts are reassembled, confirm that the recovery filter base is placed back to its original
position.
Recovery filter connecting tubes
(2 pieces)
Twist-Lock (Cable Fastener, 2 pieces)
Banding Band (4 pieces)
Twist-Lock (Cable Fastener, 2 pieces)
Recovery filter base
Fixing screw
Recovery filter base
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...