6-54
6.4.17 Inside Temperature Too High
●The Ink recovery behavior of Acetone-based ink degrades as the inside temperature
gets high.
※
Both MEK-based ink and Ethanol-based ink have similar characteristics in which the
ink recovery behavior degrades as the inside temperature gets high.
However, particular attention shall be given to Acetone-based ink.
●Follow the troubleshoot as described below to restore the situation
●When you resume the operation, confirm the recovery status first.
Inside Temperature Too High
Replace air filter and R air filter.
Refer to ”6.2.22 Inside Temperature Sensor Fault”
Is the problem fixed?
Yes
No
Is enough space secured for the printer installation?
Is the ambient temperature 35 degree C
or higher?
Yes
No
Lower the ambient temperature using an air
conditioner, etc.
Is the problem fixed?
Yes
No
Does the alarm “Cooling Fan Warning occur?
Yes
No
Refer to “6.4.15 Cooling Fan Warning”
Is the problem fixed?
Yes
No
No
Yes
Refer to “2 INSTALLING PREPCAUTIONS” in
Technical Manual and follow the described procedures
to secure enough space for the maintenance area.
Is the problem fixed?
Yes
No
Resume the operation
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...