2-6
3 Press Automatic adjustment.
During automatic adjustment, “in progress” is displayed as the processing status.
The excitation voltage is automatically adjusted inside the IJ printer.
The excitation voltage is gradually increased, and the adjustment is completed
at 360 V ± 20V p-p. (Excitation adjustment is automatically completed within 90 seconds.)
4 When completed, the processing status is displayed to be “Ended”.
5 If automatic adjustment fails, the Manual adjustment key is displayed.
Main causes of automatic adjustment failure
№
Cause
1
The connection of the EZJ126 board and EZJ125 board is insufficient.
2
The dip switch on the EZJ125 board is incorrectly set.
3
The connection of the coaxial cable connector for excitation (EZJ125 CN5) is
insufficient.
4
Replacement parts are out of order (EZJ126/EZJ125 board, nozzle, head
cable).
Proc. status: In progress
Proc. status: Ended
Adjust./oper. checkout
<Excitation adjustment>
0752
Excitation voltage value
(0-2047)
Proc. status: Failed
[Stop ]
2015.07.07 12:45
Com=0
Back
Automatic
adjustment
Manual
adjustment
Manual adjustment
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...