![background image](http://html.mh-extra.com/html/hitachi/ij-ux/ij-ux_service-manual_143794067.webp)
2-47
(4) Fault
(a) Fault occurrence condition
When Expiration date management for ink and makeup is set to Enable, the fault of “Ink
Shelf Life Information” or “Makeup Shelf Life Information” is output under conditions
below.
№
Fault output condition
1
At startup, [Present
≧
Fault output starting date]
2
Every hour 1 minute after the hour, [Present
≧
Fault output starting
date]
3
Fulfill the fault occurrence condition of (2) Input lot number)
(b) [Guidance of ink shelf life] messages
Ink Shelf
Life
Information
Text Replacement of ink is recommended.
Cause 1. It is estimated time to replace ink.
2. Ink lot number is different.
Solution 1. Use ink within its expiration date at replacement.
2. Confirm ink lot number on unit information screen.
3. Contact your local distributor.
Button
Close
(c) [Guidance of makeup shelf life] messages
Makeup
Shelf Life
Information
Text Replacement of makeup is recommended.
Cause 1. It is estimated time to replace makeup.
2. Makeup lot number is different.
Solution 1. Use makeup within its expiration date at replacement.
2. Confirm makeup lot number on unit information screen.
3. Contact your local distributor.
Button
Close
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...