4-38
(D) Pull out the viscometer IN-side tube (mark G) from viscometer.
[Caution] The ink in tube will slightly drip: Fit wiping paper to the end of tube. No
reverse flow of ink will occur inside the viscometer.
(E) Immediately lift the end of removed tube higher than the level of liquid in the main ink
tank, and then keep this for at least 10 seconds to return the ink in tube to the main
ink tank.
(F) When the ink has drained from tube and air enters in it, release your hand from the
tube. When air enters the tube, no reverse flow of ink will occur even if the tube hangs
down.
2 Disposing of ink inside viscometer
Remove any ink remaining inside before removing the viscometer.
(A) Turn power on.
(B) Use “Solenoid Valve/Pump Test” screen of “Maintenance menu” to turn on the pump
to MV4 in that order, and operate them for at least 10 seconds. (The ink remaining
in viscometer will return to the main ink tank.)
(C) Turn power off.
3 Unplugging connectors
[Caution] Do not perform this work with power turned on: Doing so will cause
“Viscometer Temperature Sensor Fault” to occur.
Unplug the connectors of lead wires at the back of circulation unit, and pull them
out forward through the edge saddle.
Proximity sensor: 4-pin; Thermistor: 2-pin (blue/black); Coil: 2-pin (blue/blue)
4 Removing viscometer
Remove the two setscrews from viscometer, and then pull the viscometer out
forward.
[Caution] Pay extra attention to remove O-ring. The O-ring might remain in the
circulation unit.
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...