6-62
6.5.5 Disordered characters
NOTICE
Do not repeat the nozzle backwash procedure more than two times.
If it is repeated to an excess, the ink becomes thin, thereby causing
disordered prints. If the ink is thin and disordered prints are
encountered, replace the ink.
Disordered
characters
Are the upper or
lower print dots
lost?
No
Yes
Is the upper end of
the print blotted?
No
Yes
Adjust the excitation voltage
and pressure to ensure
proper ink drops
generation.
Are ink drops
properly generated?
Yes
No
See under “Chipped
print”.
Ensure that the operating
temperature is within the
specified limits.
Is the operating
temperature with the
specified limits?
Yes
No
Ensure that the work surface is
free from coating application
irregularities, water drops, dirt,
oil, and other foreign matter.
Resume the
operation.
Are normal prints
obtained?
No
Yes
Replace the ink.
Are normal prints
obtained?
No
Yes
Since it is conceivable that the
ink flow path may be clogged,
clean the ink final filter and
joints, backwash the nozzle,
and disassemble and clean the
nozzle.
There is a noise on
APH wave farm.
Yes
No
Confirm the print result
With the printhead removed
From customer’s equipment.
normal prints are
obtained?
Yes
No
Ask your customer to
Remove any vibration.
Yes
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...